Related Products

Denntal Implant 1:4.2 Contra HandPiece L-A 15015 LED(Optical Fiber) Internal waterway

Standard Configuration

Dental Implant 1:4.2 Contra Angle Handpiece L-A 15015 LED (Optical Fiber)Internal waterway

Function:

Designed for precision dental implant procedures, offering smooth and stable performance.

Features a 1:4.2 speed increasing ratio for high-efficiency cutting and drilling.

Equipped with a four-point spray system for superior cooling and reduced heat buildup.

Strong needle clamping prevents flying needles, ensuring safety and accuracy.

Laser-welded external water pipe ensures a sterile and contamination-free working environment.

Minimally invasive tooth extraction with no risk of emphysema, improving patient comfort.

LED optical fiber lighting provides clear visibility in surgical areas.

Technical Specifications:

Transmission Ratio: 1:4.2

Speed: ≥15,000 RPM

Noise Level: ≤63 dB

Cooling System: Four-point spray

Water Pipe Design: Physiological saline laser welding

Material: High-quality stainless steel for durability and corrosion resistance

Lighting System: Built-in LED (optical fiber)

Safety Features: Secure clamping system to prevent flying needles

Featured Highlights Of Dental Implant 1:4.2 Contra Angle Handpiece L-A 15015 LED (Optical Fiber)Internal waterway

Check Our All Products

45-Degree Angled Head for Easy Access

With its 45-degree angle design, this handpiece provides maximum visibility and precision, making it ideal for molar extractions while minimizing interference with neighboring teeth.

Built-in Anti-Retraction System

The anti-retraction feature ensures a safe and sterile working environment by preventing contamination from backflow, which enhances patient safety during use.

Effortless Needle Replacement System

The press-button needle removal system allows for quick and secure changes, ensuring no flying needles during procedures, improving both safety and efficiency.

Advanced LED Lighting & Cooling Function

Equipped with LED optical fiber lighting for clear visibility, this handpiece also offers dual cooling options (internal or external), ensuring effective heat dissipation during treatments.

High-Speed with Quiet Operation

Reaching speeds of up to 168,000 RPM with minimal noise (≤65 dB), this handpiece ensures quiet and stable operation, reducing discomfort during procedures.

Versatile E-Type Interface

The handpiece comes with an E-type interface, ensuring compatibility with electric micromotors up to 40,000 RPM, allowing for seamless integration with various dental units.

Dental Implant 1:4.2 Contra Angle Handpiece L-A 15015 LED (Optical Fiber) Installation And Use Methods

Check Our All Products

1. Install and remove the needle/drill bit

1-1 Install

Press the back cover, insert the needle into the machine head and gently turn the needle. Push it to the bottom after it fits, and then release it until it stops. The needle is locked.

1-2. Removal

Press the back cover with your thumb and the needle can be removed.

2. Connect/disconnect the phone

2-1. Connect

Push the handle onto the motor, keep it aligned, and twist the phone until you hear a click and it locks in a certain position.

2-2. Unplug

Hold the motor and the handpiece separately and unplug directly.

Note:

Do not install or remove the handpiece before the motor stops completely.

Only connect to the motor with a maximum speed of less than 40,000 rpm (ISO3964) on the E-type handpiece.

Only connect to the motor with a stop pin.

The connector of this product complies with the ISO3964 standard.

Dental Implant Contra Angle 20:1 Handpiece Oil Injection And Maintenance

Check Our All Products

1. Cleaning

After each use, remove the needle from the mobile phone, use a brush to sweep away the debris inside and around the outlet, rinse the mobile phone under running water to remove surface contaminants.

Lubricate the mobile phone again after high-temperature sterilization. If the mobile phone has a removable head, please unscrew the head and then use air to blow the inside of the head to blow out the dirt inside the head.

2. Lubrication

The oil injector should be used with the E-type nozzle. Insert the nozzle into the mobile phone and spray for 2-3 seconds.

If it is operated continuously, please add oil every 30 minutes.

Repeat lubrication until the mobile phone is completely clean and free of debris.

Note: The mobile phone must be cleaned in time, otherwise it will affect the performance of the mobile phone.

What Sets Lavender Dental Apart

Lavender Dental is a trusted name in the dental industry, renowned for providing high-quality, reliable dental equipment to professionals worldwide. Our brand stands out for its commitment to excellence, innovative solutions, and dedication to customer satisfaction. Whether you're outfitting a new dental practice or upgrading your existing equipment, Lavender Dental is your go-to partner for superior products and unmatched expertise.